Screw Compressor Installation Calculator
Professional Engineering Tool Compliant with International Standards
Compliant with
IEC 60204-1
IEC 60364-4-43
IEC 60364-5-52
ISO 1217
Input Parameters
Unit System
India (Metric/IEC)
USA (Imperial/NEC)
IEC 60364 standards applied. Calculations use kW, m³/min, and mm units with correction factors per IEC 60364-5-52.
kW
1 kW = 1.34 HP
m³/min
1 m³/min = 35.31 CFM
Voltage Selection
230V (Single Phase)
400V/460V (3-Phase)
230V single phase for smaller installations. 400V/460V three-phase for industrial applications.
Performing IEC compliant calculations…
IEC Compliant Installation Requirements
Electrical Specs (IEC 60204-1 & 60364)
Design Current (Ib):
— A
Fuse/MCB Rating:
— A
Main Cable (Copper):
— mm² / AWG
Earthing Cable:
— mm² / AWG
Voltage Drop:
— % @ 30m
Applied Correction Factors (IEC 60364-5-52):
Ambient Temp: 1.00 • Grouping: 0.70 • Installation: 0.85Installation Specs (ISO 1217)
Minimum Room Size:
— m / ft
Ventilation Airflow:
— m³/h / CFM
Duct Size:
— mm / in
Clearance Space:
1.5 m / 5 ft
Piping Specs (ISO 4414)
Discharge Pipe Diameter:
— mm / in
Max Pipe Length:
— m / ft
Flow Velocity:
— m/s / ft/s
Pressure Drop:
< 0.1 bar / psi
System Information & Standards
Primary Standard:
IEC 60364-4-43
Power Factor (cos φ):
0.85
Motor Efficiency (η):
90%
Cable Type:
PVC Insulated Cu
—
Equivalent Power
—
Equivalent Flow
230V
Operating Voltage
Single
Phase
30°C
Ambient Temp
Important Disclaimer
This tool provides engineering estimates based on international standards: IEC 60204-1 (Safety of machinery), IEC 60364-4-43 (Overcurrent protection), IEC 60364-5-52 (Cable sizing), ISO 1217 (Compressor testing), and ISO 4414 (Pneumatic systems). Always consult a certified engineer for site-specific installations as per local codes.
- IEC 60204-1 Compliance: Motor circuit protection calculated per clause 7.2 (Overload protection) and clause 8 (Wiring practices).
- IEC 60364-5-52 Compliance: Cable sizing includes correction factors per Table 52.14-52.15 for ambient temperature, grouping, and installation method.
- IEC 60364-4-43 Compliance: Overcurrent protection per clause 433 (Protection against overload current) for motor circuits.
- Cable sizing based on PVC insulated copper conductors, installation method B2 (in conduit on wall), 3 cables in bundle, 30m cable length.
- Voltage drop limited to 5% per IEC 60364-5-52 clause 525 for motor circuits.
Note: National Electrical Code (NEC) requirements may differ for US installations. Always verify with local authorities having jurisdiction.